Disable Drill-Through Links
You can permanently disable drill-through links for all analysis reports by editing the analyzer.properties file, or you can disable drill-through links on a cube-by-cube basis. Both methods are described in these steps.
- Global Disable: Follow these steps to disable drill-through links for all cubes and analysis data sources.
- Open your analyzer.properties file with a text editor and look for the property called
report.drill.links.disabled
. - Set the value from false to true as shown here.
From:
report.drill.links.disabled=false
To:
report.drill.links.disabled=true
Drill-through links are now disabled for all cubes and analysis data sources. The option for drill-through links is no longer visible on the Report Options dialog box.
- Open your analyzer.properties file with a text editor and look for the property called
- Individual Cubes: Follow these steps to disable drill-through links on a cube-by-cube basis.
- Open the schema for the particular cube on which you want to disable drill-through links.
- Find the Cube element in the schema file and add this annotation to disable the links:
<Annotations><Annotation name="AnalyzerDisableDrillLinks">true</Annotation></Annotations>
- Save and close the schema.
Drill-through links are now completely disabled for that cube, and the option to show drill-through links is no longer visible on the Report Options dialog box for the cube.